Fire Resistant Drywall: Hidden Facts Behind 2-Hour Fire Ratings -- New Sulfate MGO Fire Rated Wallboard Versus Fire Rated Gypsum Board
- JP Group MagMatrix Brand
- Jul 27
- 14 min read
Fire resistant drywall is a vital but often overlooked part of building safety. The last decade saw more than 35,000 structures destroyed by wildfires. This alarming number shows why we need reliable fire protection systems in our homes and businesses.
The science behind fire-resistant drywall's effectiveness is the sort of thing I love.
Gypsum, the main material used in fire-rated drywall, contains about 21% chemically combined water. This water acts as a natural fire deterrent. The drywall's fire resistance can last up to 4 hours because of this water content and special additives. Type X and Type C are the most common types of fire-resistant drywall, each offering different protection levels. Type X gives you 1 to 2 hours of resistance. Type C can last even longer than 2 hours, which makes it ideal for spaces that need extra safety measures.
Fire-resistant drywall does more than just slow down flames. The design specifically stops heat from spreading through walls. Gypsum board walls won't let temperatures rise above 212°F until all the gypsum completely calcines. This feature is a vital part of keeping buildings stable during fires and gives people more time to escape safely.
To versus the fire rated drywall board, here the MgO board (Magnesium Oxide board) is a versatile, durable, and fire-resistant building material used in residential, commercial, and industrial construction. It’s made primarily from magnesium oxide (MgO),sulfate, perlite, and reinforcing fibers, forming a strong, non-toxic cement board.

Gypsum Chemistry and Fire Resistance Explained
Gypsum drywall's amazing fire-resistant properties come from its chemical makeup. The chemistry behind it explains why these products work so well to stop fires from spreading in today's buildings.
Calcium Sulfate Dihydrate and Water Content
Gypsum's chemical identity is calcium sulfate dihydrate (CaSO₄·2H₂O), a natural mineral with a remarkable feature. Each calcium sulfate molecule bonds with two water molecules in its crystal structure. The name "dihydrate" directly points to these water molecules.
The water in gypsum isn't just moisture soaked up from the air - it's built right into the mineral's structure. This crystal water makes up about 21% of gypsum's total weight. A quick calculation shows that CaSO₄·2H₂O has about 21% water by mass. A gypsum core that has 85% CaSO₄·2H2O by mass with a density of 650 kg/m³ holds a potential water density of 116 kg/m³.
Gypsum boards usually hold a small amount (≤4%) of free water. Commercial gypsum boards also have other materials like calcium carbonate (CaCO₃) and magnesium carbonate (MgCO₃) that help them resist fire better.
Steam Release and Heat Absorption During Calcination
Calcination happens when heat removes water from gypsum. This change involves specific chemical reactions that improve fire resistance by a lot.
Heat starts removing water at temperatures between 80°C and 250°C, depending on how fast things heat up. This happens in two main steps:
1. First step (around 100-125°C): Calcium sulfate dihydrate loses 75% of its water and becomes calcium sulfate hemihydrate (CaSO₄·½H₂O).
2. Second step (125-225°C): Calcium sulfate hemihydrate loses its last bit of water and turns into calcium sulfate anhydrate (CaSO₄).
Both these reactions soak up energy from their surroundings. They use up a lot of heat that would otherwise make nearby building materials hotter. Fire testing experts often see temperatures stay around 100°C on the protected side of gypsum panels because of this.
The molecular structure changes again at higher temperatures (about 400°C) as the soluble anhydrate shifts to a lower energy state. Unlike earlier changes, this one releases a small amount of energy.
Why Gypsum Delays Heat Transmission
Several physical and chemical processes work together to make gypsum resist fire so well.
The water-removing reactions act like heat sponges and soak up lots of energy during a fire. Rising temperatures turn the bound water into steam, which slows down heat moving through the material. The temperature where calcination happens stays just above 212°F (100°C) - this is a big deal as it means that it's much cooler than temperatures that weaken steel or set wood on fire.
Steam moving through the board creates another protective layer. Water vapor travels through tiny holes in the gypsum board. It might turn back into water in cooler spots, which releases energy but keeps that area's temperature steady. This cycle keeps going as heat moves through the material.
Gypsum won't let heat above 212°F pass through until all of it turns into powder. This gives people vital time to escape during fires and helps buildings stay standing.
The powdered gypsum keeps working as a barrier even after all the water leaves, and it blocks flames from reaching structural parts underneath. This layered defense system shows why fire-rated gypsum products are the foundations of modern fire safety strategies.
Understanding the 2-Hour Fire Rating System
Fire-resistant drywall must meet strict standards to provide measurable protection in buildings. A "2-hour fire rating" represents complex testing procedures that manufacturers must complete. These methods help measure how long construction materials can withstand fire exposure before they fail.
ASTM E119: Fire Endurance Test Parameters
ASTM E119 serves as the main test method to determine fire resistance ratings in the United States. This standard helps review how long building elements can contain fire and maintain structural integrity during controlled fire exposure. The test subjects specimens to carefully controlled temperatures that follow a standard time-temperature curve. The furnace temperatures reach 538°C (1,000°F) in five minutes and rise to 1093°C (2,000°F) after four hours.
The test looks at several key factors:
3. Heat transmission through the assembly
4. Passage of hot gasses through the specimen
5. Load-carrying ability during fire exposure (for load-bearing elements)
6. Structural integrity throughout the test period
ASTM E119 tests complete assemblies rather than individual parts. This explains terms like "fire-rated wall assemblies" or "fire-rated floor and ceiling assemblies". This comprehensive method recognizes that fire resistance depends on materials working together as integrated systems.
UL 263: Assembly-Based Fire Rating Standards
UL 263 (Underwriters Laboratories) matches ASTM E119 in its methods and requirements. This standard reviews assemblies of masonry units and composite assemblies of structural materials for buildings. It follows the same time-temperature curve and applies to walls, floors, ceilings, columns, beams, and other structural building elements.
UL 263 ratings show the time period an assembly withstands fire exposure while maintaining performance criteria. Common ratings include "W-60" for one-hour ratings and "W-120" for two-hour ratings. The International Building Code (IBC) accepts both ASTM E119 and UL 263 as equal standards for fire resistance requirements.
These standards share similar aspects, but UL 263 requires mandatory recording and reporting of furnace pressure. Experts say this is the main difference between these otherwise similar standards.
Thermocouple Thresholds and Hose Stream Test
Thermocouple measurements provide clear criteria to determine when an assembly fails under fire conditions. Gypsum board assemblies must meet specific temperature thresholds to pass ASTM E119:
· Average temperature across all thermocouples on the unexposed surface cannot exceed 250°F above ambient temperature
· No single thermocouple can go beyond 325°F above ambient temperature
· Maximum temperature on steel members cannot exceed 1,100°F for assemblies containing structural steel
These thresholds are the foundations of safety benchmarks. The 325°F limit exists because this temperature could ignite combustible materials through heat transfer alone.
Most vertical assemblies must pass both the fire endurance test and the hose stream test. The hose stream test offers a demanding review of structural integrity. A duplicate specimen receives a high-pressure water stream according to standard parameters after fire exposure, which typically lasts half the fire endurance period but no more than one hour. This test checks resistance to:
· Impact from falling debris
· Thermal shock
· Erosion effects
Two-hour fire rated drywall assemblies must withstand this water stream without letting water pass through. While not meant to simulate firefighting, this tough assessment proves that fire barriers stay strong under extreme conditions.
These standards create reliable metrics for builders and occupants to review fire protection performance across different construction materials and methods.
Type X vs Type C Fire Resistant Drywall
Fire resistant variants of drywall products are a vital protection upgrade from standard options. The differences between Type X and Type C fire rated drywall go beyond simple classifications. These differences show up in how well each type performs.
Glass Fiber Reinforcement in Type X
Type X gypsum board became the industry's first fire-code product in the mid-20th century. The first wall assembly that achieved a 1-hour fire rating came about in 1947. ASTM C36 officially defined Type X drywall in the 1950s. Glass fibers added to the gypsum slurry during manufacturing boost its fire resistance. These fibers play a vital role by reinforcing the gypsum core as it calcines under heat exposure.
The fibrous reinforcement helps limit cracks from forming as water evaporates from the gypsum core. This support helps the panel stay intact during fire conditions. ASTM C1396 sets specific requirements for Type X gypsum board. A 5/8" Type X board must provide at least a 1-hour fire rating on both sides of wood studs.
Vermiculite Expansion in Type C
Type C drywall lifts fire protection by adding more defensive features. It contains a higher percentage of glass fibers by weight compared to Type X. In spite of that, vermiculite additives that expand by a lot at high temperatures make Type C unique. This expansion helps counter the shrinkage that happens as gypsum calcines.
The vermiculite in Type C boards expands right around the same temperature where gypsum calcination occurs during a fire. This timing lets Type C panels keep their shape even after losing their water content. The expansion is especially helpful at board joints and seams, which are often weak points in fire-rated assemblies.
Fire Resistance Duration: 1 Hour vs 2+ Hours
These board types show clear differences under fire conditions. Type X usually provides 1-hour fire resistance at 5/8-inch thickness. Some setups can reach 2-hour ratings. Type C boards last longer than 2 hours and can reach 3-hour ratings in certain setups.
One manufacturer's test showed a big difference between the two products. They exposed both to 1580°F (860°C) with a weight in the middle. The Type X panel failed after 57 minutes. The Type C panel showed no damage even after 2 hours and 2 minutes. This is why many critical applications require Type C.
Thickness and Application Differences
Type X and Type C drywall are thicker than standard drywall. Type X comes in 5/8-inch thickness, about 1/8-inch more than regular drywall. You can get Type C boards in both 5/8-inch and 1/2-inch sizes. Most manufacturers don't make 1/2-inch Type X, so some specs for this thickness actually need Type C products.
Each type works best in different places. Type X works great in wall assemblies for homes and commercial buildings, especially in fire-prone areas like kitchens and boiler rooms. Type C boards work better in horizontal setups - ceilings, floor-ceiling systems, and horizontal shaftwall systems. This preference comes from Type C's better performance when installed horizontally.
High-risk areas often need special protection. Type C drywall goes into stairwells and elevator shafts where fire moves up faster. Many UL-listed floor and ceiling assemblies specifically need Type C instead of Type X. Type C can also reduce the layers needed - one layer with resilient channels can replace two layers of Type X in some floor-ceiling setups.
Fire Rated Assemblies and System Design
Fire resistance starts with well-laid-out assemblies. Even the best fire rated drywall won't work as intended without proper supporting structures, fasteners, and installation methods. A fire-resistant system works best when you treat it as one complete unit rather than separate parts.
Role of Studs, Fasteners, and Installation
The structural framework that supports fire rated drywall plays a crucial role in fire resistance integrity. Metal stud thickness directly affects performance—Type S screws work with steel less than 33 mil thick, while Type S-12 screws are needed for thicker steel. These fasteners should go at least 5/8 inch into wood framing and 3/8 inch into metal framing.
Proper fastener spacing makes a big difference. A one-hour wall assembly (UL Design U465) needs fasteners 8 inches on center along board edges and 12 inches on center in the field. Two-hour designs have their own requirements—UL Design U411 calls for base layer attachment at 16-inch spacing, and face layer needs 16-inch spacing in the field with 12-inch spacing at floor and ceiling tracks.
Poor installation can ruin effectiveness. A screw loses its holding power when it crushes the gypsum core beneath its head. Screws installed at angles don't hold well either. Your fasteners should be installed:
· Perpendicular to the gypsum board
· Between 3/8 and 1/2 inch from edges
· With heads just below the paper surface without breaking it
Walls must stand up to both flames and impact forces during fires. The hose stream test proves this—a one-hour fire-rated wall needs to handle water at 30 psi pressure for one minute without letting water through.
Multi-layer Drywall Configurations
Adding multiple layers of drywall substantially boosts fire resistance. You'll often see double or multi-layer applications where you need extra fire protection or sound isolation. Using adhesive for the outer layer makes everything stronger, though fire codes usually still want all standard fasteners.
The right technique matters when installing multiple layers. Each layer needs the right number of fasteners at the right depth—don't just "tack" initial layers and fully fasten only the last one. A good approach puts the first layer parallel to framing members and the second layer perpendicular, with seams at least 10 inches apart.
Two-hour ratings typically use this setup:
7. Base layer attached with 1-inch minimum screws
8. Face layer secured with 1⅝-inch screws
Advanced designs can get creative. UL design V449 takes a standard one-hour wall (one layer of ⅝" Type X on each side) and turns it into a two-hour assembly by adding two more layers to just one side. One-sided assemblies are great for renovations.
Common Use Cases: Garages, Utility Rooms, Stairwells
Building codes often require fire rated drywall in high-risk areas. Garages are a prime example because they store flammable materials like gasoline, oil, and paint. Walls and ceilings between garages and living spaces usually need Type X drywall (⅝ inch thick).
Utility rooms with water heaters, furnaces, or electrical panels pose higher fire risks and usually need fire rated assemblies. Walls between living spaces and attached garages must have fire rated drywall to slow down fire spread.
Stairwells deserve extra attention as escape routes. Under-stair spots usually meet fire separation requirements with ⅝" Type X or C drywall. Some installations combine mineral wool/rockwool insulation with double layers of 5/8" drywall (seams mudded) and intumescent paint for better protection.
Fire-rated assemblies come in different levels, from one-hour designs for homes and simple commercial uses to four-hour setups for buildings storing flammable chemicals. Type X gives you one-hour protection, while Type C works best in two-hour and three-hour rated systems.
Every part of the system—fasteners, framing, and drywall type—works together to protect lives and property when fires break out.
Flame Spread and Smoke Development Ratings
Drywall products must pass more than just time-based fire resistance tests. Safety experts need to learn about how these materials behave in real fire conditions. This information helps them understand safety risks beyond structural failures.
ASTM E84: Surface Burning Characteristics
ASTM E84, known as the Standard Test Method for Surface Burning Characteristics of Building Materials, helps experts assess how materials react when exposed to flames. This standard test measures two vital properties: flame spread speed across surfaces and smoke production during burning. Scientists conduct these tests in a specialized chamber called the Steiner Tunnel. The setup includes a 24" x 24" wide space where they mount test materials on the ceiling, facing down toward the ignition source.
The test runs for 10 minutes with controlled airflow and burners that provide 89kW of energy each. Special lighting systems measure optical density to calculate smoke production. Results are compared against two standard materials: asbestos-cement board (rated 0) and red oak (rated 100).
Class A Rating: Flame Spread Index 0–25
Building codes use ASTM E84 results to classify materials. Class A represents the highest safety standard. Materials need a Flame Spread Index (FSI) between 0-25 and a Smoke Developed Index (SDI) below 450. Class B materials have an FSI of 26-75, while Class C materials range from 76-200. Both classes must stay under the same 450 SDI limit.
Fire-resistant drywall products typically achieve Class A ratings. To name just one example, some gypsum boards score a flame spread rating of 15, which beats the Class A requirements by a wide margin. Premium products perform even better with zero flame spread ratings.
Smoke Developed Index and Visibility in Fires
Smoke poses greater dangers than flames in many fire situations. Dark, thick smoke makes it hard for people to find their way out of burning buildings. Building codes restrict smoke development and flame spread because of these risks.
The Smoke Developed Index helps experts calculate smoke-related dangers. Lower numbers mean safer conditions. Materials with high SDI ratings create dangerous situations in crowded or confined spaces. Many high-quality fire resistant drywall products achieve zero SDI ratings in ASTM E84 tests. This means they produce almost no smoke during fires.
Building codes set specific requirements for both flame spread and smoke ratings. These requirements change based on building type and use. The International Building Code states that wall and ceiling finishes must have a flame spread index of 200 or less and keep the smoke-developed index under 450.
Advanced Fire-Resistant Materials and Innovations
Modern construction has better alternatives to traditional fire-resistant materials. These breakthroughs protect better and work better in many ways.
Fire Rated MgO Board vs Gypsum Board
MgO boards are better than regular gypsum products. They resist fire naturally without chemicals and have fire ratings up to 4 hours. Standard fire-rated gypsum lasts only 30 minutes to 1 hour. MgO boards have a zero flame spread rating and stay stable when heated, while gypsum breaks down in extreme heat.
MgO boards resist moisture and mold better. They don't contain harmful chemicals like formaldehyde, which makes indoor air safer.
Elevate your building projects with MgO boards—engineered for unmatched durability and reliability. Magnesium oxide boards combine strength, fire resistance, and moisture protection, making them the go-to solution for contractors, builders, and architects who demand excellence.
Built to withstand the most challenging conditions, MgO boards excel in providing long-term structural integrity while ensuring safety and peace of mind for the environment. From enhancing interior spaces to fortifying exterior walls, they redefine what’s possible in modern construction.
Key Benefits
Exceptional Strength and Durability
With superior impact resistance, MgO boards withstand environmental wear and tear, outlasting traditional materials such as wood or gypsum.
Fire Resistance You Can Trust
Non-combustible and ideal for fire-rated assemblies, MgO boards help protect your builds from the unexpected.
Moisture Protection, Inside and Out
Unlike wood and drywall, MgO boards resist swelling, deformation, and breakdown, even in wet conditions.
Naturally Mold and Mildew Resistant
Breathe easier with materials designed to curb mold growth for healthier indoor air quality.
Simplified Installation
Easily cut, drilled, and fastened using standard tools—no specialized equipment required.
Eco-Friendly Innovation
Made without toxic chemicals like asbestos or formaldehyde, MgO boards support a greener future.
Versatile Applications
Exterior Sheathing
Reinforce walls with added strength, fire resistance, and moisture protection.
Interior Walls and Ceilings
Create durable, fire-safe spaces with a sleek, professional finish.
Siding and Flooring Underlayment
A dependable base for siding installations and flooring projects.
Fire-Rated Assemblies
Ideal for walls and ceilings that meet strict fire safety standards.
Build Smarter, Build Better
Choose MgO boards for performance, versatility, and peace of mind that exceeds expectations. Whether it’s a commercial high-rise or a cozy home, MgO boards deliver results you can rely on.
GlasRoc® and M2Tech® Product Features
GlasRoc Interior Drywall uses reinforced fiberglass mat facers that make it exceptionally strong. M2Tech Shaftliner has a 1" thick panel with a special fire-resistive core.
M2Tech technology resists fire for up to four hours (Type X) and fights mold growth better. Both products meet GREENGUARD Gold certification standards for low VOC emissions.
Moisture and Mold Resistance in Fire-Rated Panels
These advanced panels excel at stopping moisture damage. M2Tech scores a perfect 10 for mold resistance in ASTM D3273 tests. It absorbs less than 5% water after two-hour immersion.
The panels keep their fire-protective properties while fighting moisture. This makes them perfect for tough spots like bathrooms and kitchens where you need both features.
Conclusion
Fire-resistant drywall is a vital part of modern building safety. It provides protection that can make the difference between minor damage and total loss. The remarkable chemistry of gypsum contains 21% chemically combined water that creates a natural defense against flames. This built-in moisture absorbs heat energy and slows down temperature rise during fires. People get precious time to escape.
Type X and Type C drywall make a big difference when designing fire-resistant structures. Type X gives 1-hour protection, while Type C contains vermiculite additives that provide over 2-hour ratings. This makes Type C perfect for stairwells and elevator shafts. The right material choice for specific building areas matters a lot for safety.
Testing standards like ASTM E119 and UL 263 help us understand fire ratings better. These standards make sure all building materials and assemblies get tested the same way. The thorough approach measures heat transmission, structural integrity, and resistance to water pressure. Fire ratings show how materials work in real-life situations rather than just theory.
Good materials need proper installation to work well. The type of fasteners, their spacing, and how they're installed affect how well these systems handle actual fires. Even the best fire-rated drywall needs correct supporting structures and installation methods to protect properly.
Building technology keeps improving. New materials like MgO boards, GlasRoc, and M2Tech panels offer better protection and resist moisture and mold. These materials solve many building challenges at once and create safer buildings.
You can't see fire-resistant drywall behind paint and decorative finishes, but it's one of the most important parts of any building. The science, testing standards, and careful installation work together. They create buildings that fight flames, control smoke, and protect property and lives when fires happen.



![MGO Board vs Drywall: Which Lasts Longer? [2025 Test Results]](https://static.wixstatic.com/media/094d17_ecdebcfd0017441fafb7ef1dcaf95bd1~mv2.jpg/v1/fill/w_980,h_583,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/094d17_ecdebcfd0017441fafb7ef1dcaf95bd1~mv2.jpg)
Comments